Description
100 milliamp 2 Channel 3 Mode Digital Muscle Stim Unit with Timer
Powerful (100mA) Muscle Stim unit with powerEAZE™ recharge kit. Rubber-grip sides and hinged front panel for easier access to digital mode, pulse and timer controls. Comes complete with instruction manual, leadwires, 4 electrodes, sturdy carrying case, and powerEAZE™ recharge kit: 9V NiMh rechargeable battery and wall charger.
Features
Dual Channel
Safety amplitude cover prevents bumping of controls
3 Modes: Alternating, Synchronous, Constant
Control treatment time automatically (5 to 60 min) or use continuously
Record up to 999 hours of treatment time
Hinged front panel for access to digital mode, pulse and timer controls
Durable METAL Belt Clip
3 Year Replacement Warranty
Technical Specifications
Channels: Dual Channel, isolated between channels
Pulse Amplitude: Adjustable, 0-100 mA peak into 500 ohm load each channel.
Voltage: 0 – 50V (Load: 500 ohm)
Pulse Rate: Adjustable, from 2 to 150 Hz, 1 Hz/step
Pulse Width: Adjustable, from 50 to 300 microseconds, 10uS/step
Wave Form: Asymmetrical Bi-Phasic Square Pulse
On Time: Adjustable, 2~90 seconds , 1 Sec./ step
Off Time: Adjustable, 2~90 seconds , 1 Sec./ step
Ramp Time: Adjustable, 1~8 seconds, 1 Sec./ step, The “On” time will increase and decrease in the setting value.
3 Modes: Constant ,Synchronous, Alternate
Constant stimulation: based on setting value. Only pulse width, pulse rate and timer are adjustable in this mode. “Constant” is equal to the “Normal” mode of a TENS unit.
Synchronous: Stimulation of both channels occurs synchronously. The “ON” time including “Ramp Up” and “Ramp Down” time. Therefore, the setting of ON Time should be no less than two times of the “Ramp” time in this mode. ON TIME > ?Ramp up + Ramp down
Alternate: The stimulation of the CH2 will occur after the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the “Ramp” time. The OFF Time should be equal or more than the ON Time. ON TIME > ?Ramp up + Ramp down OFF TIME >ON TIME
Patient Compliance Meter: This unit can store 60 sets of operation records. Total recorded time is 999 hours.
Timer: Adjustable, from 5 to 60 minutes or Continuous. Adjustable in 5 minutes each step. Treatment time countdown automatically.
Warranty: 3 Year Manufacturer Warranty
System Includes: Stimulator, Lead Wires, 4 high quality Self-Adhesive Electrodes, 9V Battery, Hard Plastic Carrying Case, Instruction Booklet.
*** A PRESCRIPTION IS REQUIRED UNLESS YOU ARE A HEALTH PROFESSIONAL OR RESELLER. PLEASE FAX TO 1-866-682-7756 OR EMAIL TO SALES@TENSPRODUCTS.COM ***